AUTOPSTENHOJ - STENHØJ A/S

AUTOPSTENHOJ

STENHØJ A/S
info@autopstenhoj.com
Barrit Langgade 188-190
DK- 7150 Barrit

AUTOPSTENHOJ - autop Maschinenbau GmbH

AUTOPSTENHOJ

autop Maschinenbau GmbH
info@autopstenhoj.com
Sandkampstr. 90
D-48432 Rheine

Emissionmaster SGA400 Combi

Emission tester

Emissionmaster SGA400 Combi

Description

  • Gas analyzer incl. Lambda
  • With printer (thermal printer)
  • 7m Hose and probe in stainless steel
  • Power cable
  • Aqua sense:
    protects the optical bench from being damaged of liquids if those would enter the analyzer
  • Fast warum up time:
    The warum up time of the optical bench is less than 10 seconds and full accurasy is reached wihtin 2 minutes of running
  • Optical IR bench:
    Solid state detector, OIML calss 00 with latest technologies and highest accuracy available
  • Smoke analyzer for diesel vehicles
  • Light absorption partial flow opaciemeter
  • Vehicle test time is less than 3 minutes
  • Two test programs included
  • Automatic zeroing
  • Linearity test
  • Diesel smoke opacity is measured in smoke density % (also known as Hartridge HSU units) as well as in absorption coefficient k (m- 1).
    The readings of the k and % opacity values are displayed simultaneously.
  • Upgrades:
    New firmware can be downloaded via USB. Much quicker and more reliable than earlier proms
  • Measurement:
    Both accuracy and resolution are improved comparing with precursor
  • Reliability: 12 months calibration interval
Warm up time <10 sec
On-board voltage 10-30 VDC (with transformer)
Power supply 100-240 VAC, 50-60Hz
Dimensions (L x W x H) 400mm x 240mm x 260mm
Weight 5,3 Kg
Accuracy class 0 (OIML)
Flow min. 5,5 l/min, nominal 6,5 l/min
Measureable gases CO, HC, CO2, O2
CO - Measurement range / Measured value resolution 0 - 10 % / 0,01
CO2 - Measurement range / Measured value resolution 0 - 20 % / 0,01
HC - Measurement range / Measured value resolution 0 - 15000 ppm / 1
O2 - Measurement range / Measured value resolution 0 - 25 % / 0,01
Warm up time 3 min
Detector / light source Silizium photodiode / green LED 565nm
Absorption coeeficient (range / resolution) 0-16.06 m-1 / 0,01 m-1
Optical path length 215mm corrected to 430mm according to ISO 11614
Measurement range turbidity (range / resolution) 0-99,9% / 0,1%
more details

Versions

Stand-alone device for petrol, LPG and diesel vehicles (mobile stand with wheels optional)

Options

 

  • OBD scanner
  • Hand terminal with LCD dispay
  • Calibration gas
  • Mobile stand
  • RPM sensor via battery sytsem or piezo electronic system with 6mm clamp
  • Oil temp. Sensor
  • Option NOx